Research of Biophysical Influence on Model Physical Systems form the Students of Walter Luebeck

Ignat Ignatov, Oleg Mosin

Abstract


This paper presents the results of evaluation of possible biophysical methods and approaches for registering of various non-ionizing radiation (NIR) wave types of the human body in the electromagnetic and optical range. Many types of NIR (electromagnetic waves, infrared radiation, thermo radiation, bioluminescence) emitted from the human body were reviewed. In particular the results on of spontaneous biophoton emission and delayed luminescence from the human body are submitted along with infrared thermography (IRT) results. It was shown that 1 cm2 of skin generally emits ~85 photones for 1s. The intensity of biophoton emission ranges from 10−19 to 10−16 W/cm2 (approx. ~1–1000 photons.cm-2.s-1). The specific photon emission from part of the human thumb was detected as a spectrum of various colors with the method of Color coronal spectral analysis on a device with an electrode made of polyethylene terephthalate (PET hostafan) with applied electric voltage 15 kV, electric impulse duration 10 ms, and electric current frequency 15 kHz. It was established that photons corresponding to a red color emission of visible electromagnetic spectrum have energy at 1.82 еV. The orange color of visible electromagnetic spectrum has energy at 2.05, yellow – 2.14, blue-green (cyan) – 2.43, blue – 2.64, and violet – 3.03 eV. The reliable result measurement norm was at E ≥ 2.53 eV, while the spectral range of the emission was within 380–495 nm and 570–750 nm±5 nm. Also were estimated some important physical characteristics (energy of hydrogen bonds, wetting angle, surface tension) of water by the methods of non-equilibrium energy (NES) and differential non-equilibrium energy (DNES) spectrum of water, that helps understand in general how electromagnetic radiation interacts with water and establish the structural characteristics of water.

Keywords: electromagnetic waves, infrared radiation, thermo radiation, bioluminescence, color coronal spectral analysis, NES, DNES


Full Text: PDF
Download the IISTE publication guideline!

To list your conference here. Please contact the administrator of this platform.

Paper submission email: JMPB@iiste.org

ISSN 2422-8427

Please add our address "contact@iiste.org" into your email contact list.

This journal follows ISO 9001 management standard and licensed under a Creative Commons Attribution 3.0 License.

Copyright © www.iiste.org